Api 620 Code

API 650, Appendix V, provides the normal operating external pressure range as 0.25 kPa (0.036 lbf/in 2) to 6.9 kPa (1.0 lbf/in 2).I understand API 620 tanks stipulates the maximum partial vacuum to be at least 1 in. The Manufaacturer of a loww-pressure stoorage tank thaat will bear the APPI 620 nameplate shall ensuure that the tank is constructedd in accordancce with the reqquirements of this standard.

Api 620 Code

Api 620 Code 43

API 620 - Do ALL 'T' Joints Require RT?

620

API 620 - Do ALL 'T' Joints Require RT?

Api 620 Tank Code

Dear Sirs,
We presently have a 316L matl 3/8' wall thk. cyclone separator (F&D head & cone bottom) that the Client has speced out to API 620 Code. The operating temp is 215 deg F and design temp is 300 deg F, op pressure is 3 psig to 5 in. wc vacuum and design pressure is 7.5 psig to 15 in. wc vacuum.
Client test reqs are 10 psig hydro and spot RT w/ 85% jnt efficiency.
API 620 states in 5.26 Radiographic/Ultrasonic Examination
5.26.4.3 (a) When parts of tanks do not require complete examination, circumferential joints in cylindrical or conical surfaces need to be prepared and examined for a distance of only 3 in. on each side of any intersection with a longitudinal joint. All joints in a spherical, torispherical, or ellipsoidal shape or in any other surface or double curvature shall be considered longitudinal joints.
Does this mean that ALL 'T' type joints (circ.-to-long seams) REQUIRE RT?
Appreciate your interpretation and comments,
Robert